Tuesday, October 23, 2007

1052002 Error writing to server

Possible Problems
Analytic Services cannot write to Analytic Server, probably because Analytic Server was stopped incorrectly.

Possible Solutions
Check to see if Analytic Server is running.
If Analytic Server is not running, restart Analytic Server.
If Analytic Server crashed, follow the procedures for an abnormal shutdown.
If Analytic Server is frozen, stop Analytic Server and follow the procedures for an abnormal shutdown. If you cannot stop Analytic Server using the standard methods, end the task.
Make sure that the block size is within the recommended range.
Make sure that the license number is correct and that the license number supports all the features that you are using. If you just migrated, make sure that you followed the migration information correctly. Check the Analytic Services Installation Guide.
Check to see if the security file is corrupt.
Make sure that you have enough disk space.
Check to see if any databases are corrupt.

No comments: